All public logs
Combined display of all available logs of ASDSO Dam Safety Toolbox. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
- 17:58, 23 June 2022 Camrenbt talk contribs created page File:PTD2.jpg
- 17:58, 23 June 2022 Camrenbt talk contribs created page File:PTD1.jpg
- 17:58, 23 June 2022 Camrenbt talk contribs created page Pipe too deteriorated? Sliplining is not an option. (Created page with "<div style= "text-align:center;">''Message: It is important to understand the condition of the existing pipe before considering sliplining as a viable option.''</div> ----</br> In this Alaska dam, the principal outlet conduit was in need of rehabilitation. The pipe was a good candidate for sliplining and the condition of the pipe allowed for a successful rehabilitation. However, the dam also had an auxiliary overflow conduit that was in need of rehabilitation. As shown...")
- 17:58, 23 June 2022 Camrenbt talk contribs uploaded File:PTD6.jpg
- 17:58, 23 June 2022 Camrenbt talk contribs uploaded File:PTD5.jpg
- 17:58, 23 June 2022 Camrenbt talk contribs uploaded File:PTD4.jpg
- 17:58, 23 June 2022 Camrenbt talk contribs uploaded File:PTD3.jpg
- 17:58, 23 June 2022 Camrenbt talk contribs uploaded File:PTD2.jpg
- 17:58, 23 June 2022 Camrenbt talk contribs uploaded File:PTD1.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs created page File:GIB4.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs created page File:GIB3.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs created page File:GIB2.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs created page File:GIB1.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs created page ⚠ Gather Information Before Design (Created page with "<div style= "text-align:center;">''Message: Pulling a "Smart Pig" through the existing conduit can identify if sliplining is a possibility.''</div> ----</br> This project sought to rehabilitate a 100 year-old outlet conduit. The existing conduit consisted of a 24” diameter Riveted Steel Pipe conduit with Corrugated Metal Pipe extension installed when the dam was enlarged. The proposed rehab design was to slipline a 20" OD SDR 15.5 HDPE pipe and grout the annular space...")
- 17:50, 23 June 2022 Camrenbt talk contribs uploaded File:GIB4.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs uploaded File:GIB3.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs uploaded File:GIB2.jpg
- 17:50, 23 June 2022 Camrenbt talk contribs uploaded File:GIB1.jpg
- 17:45, 23 June 2022 Camrenbt talk contribs created page File:Low-Level Conduits - Rehab or Replace?.pdf
- 17:45, 23 June 2022 Camrenbt talk contribs created page Rehab vs. Replacement (Created page with "Can you rehab or do you need to replace? The first question the designer needs to ask is whether the conduit should be replaced or is a good candidate for rehabilitation. Conduit replacement is likely the approach providing the greatest reliability, but that approach will most likely require draining of the reservoir and be the highest cost option. In some cases, rehabilitation provides a reasonable alternative. Rehabilitation Replacement Abandonment '''Ad...")
- 17:45, 23 June 2022 Camrenbt talk contribs created page Existing Conditions (Created page with "Before beginning any project pertaining to your dam's outlet works, it is very important to understand the current condition of the conduit. Many conduits may initially look decent, but further investigation shows that the pipe is in need of repair. Missing coatings, corrosion at joints, poor gate condition, and missing corrosion protection are "red flags", and indicate the need for careful intervention. *Pipe Deterioration *Seepage and Piping *Operation *E...")
- 17:45, 23 June 2022 Camrenbt talk contribs uploaded File:Low-Level Conduits - Rehab or Replace?.pdf
- 17:22, 23 June 2022 Camrenbt talk contribs created page File:GPS3.jpg
- 17:22, 23 June 2022 Camrenbt talk contribs created page File:GPS2.jpg
- 17:22, 23 June 2022 Camrenbt talk contribs created page File:GPS1.jpg
- 17:22, 23 June 2022 Camrenbt talk contribs created page Closed Conduit Television Camera (Created page with "<div style= "text-align:center;">''Message: Using a mobile video camera mounted on a sled is a cost effective method to inspect straight conduits''</div> ----</br> Utilizing a CCTV camera mounted on a self-propelled robotic crawler is the most common way to effectively inspect a CMP conduit. An operator controls the movement of the crawler and the operation of the CCTV camera. Real-time video is transmitted to an aboveground monitor, which the operator uses to determine...")
- 17:22, 23 June 2022 Camrenbt talk contribs uploaded File:GPS3.jpg
- 17:22, 23 June 2022 Camrenbt talk contribs uploaded File:GPS2.jpg
- 17:22, 23 June 2022 Camrenbt talk contribs uploaded File:GPS1.jpg
- 17:16, 23 June 2022 Camrenbt talk contribs uploaded a new version of File:Erosion2.jpg
- 17:14, 23 June 2022 Camrenbt talk contribs created page File:Erosion3.jpg
- 17:14, 23 June 2022 Camrenbt talk contribs created page File:Erosion2.jpg
- 17:14, 23 June 2022 Camrenbt talk contribs created page File:Erosion1.jpg
- 17:14, 23 June 2022 Camrenbt talk contribs created page Erosion/Energy Dissipation (Created page with "The terminal end of an outlet works must be designed to resist erosion. Should the decision be made to rehabilitate a dam, lack of consideration of erosion in the stilling basin could result in damage to a newly installed system. <gallery mode="slideshow"> File:Erosion1.jpg File:Erosion2.jpg File:Erosion3.jpg </gallery> ==Types of Erosion== *Headcuts in stream can lead to failure *Erosion that cuts into the toe of dam can cause embankment instability Categ...")
- 17:14, 23 June 2022 Camrenbt talk contribs uploaded File:Erosion3.jpg
- 17:14, 23 June 2022 Camrenbt talk contribs uploaded File:Erosion2.jpg
- 17:14, 23 June 2022 Camrenbt talk contribs uploaded File:Erosion1.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM8.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM7.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM6.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM5.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM4.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM3.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM2.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page File:GPM1.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs created page Go-Pro Mounted on a Sled (Created page with "<div style= "text-align:center;">''Message: Using a mobile video camera mounted on a sled is a cost effective method to inspect straight conduits.''</div> ----</br> Using a mobile video camera, such as a GoPro®, mounted on a sled is a cost effective method to inspect straight (without bends or undulations) conduits, especially conduits at remote dam sites given its small size and ease of transport. The sled can be easily manufactured and attached to a metal push pipe w...")
- 17:09, 23 June 2022 Camrenbt talk contribs created page Investigation Methods (Created page with "==Camera Inspections== Unmanned camera inspections can include the use of manually or power propelled systems equipped with still, real-time and recorded video, and/or closed circuit television (CCTV) cameras. Camera inspections are beneficial because manned entry is not required, small diameter conduit can be inspected, the recording can be compared to previous recodings, and an engineer can perform an off-site evaluation. Hiring an experienced camera operator is import...")
- 17:09, 23 June 2022 Camrenbt talk contribs uploaded File:GPM8.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs uploaded File:GPM7.jpg
- 17:09, 23 June 2022 Camrenbt talk contribs uploaded File:GPM6.jpg