All public logs
Combined display of all available logs of ASDSO Dam Safety Toolbox. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
- 20:50, 22 June 2022 Camrenbt talk contribs uploaded File:SIP1.jpg
- 23:09, 21 June 2022 Camrenbt talk contribs created page File:SP2.jpg
- 23:09, 21 June 2022 Camrenbt talk contribs created page File:SP1.jpg
- 23:09, 21 June 2022 Camrenbt talk contribs created page Seepage and erosion around the conduit must be taken seriously (Created page with "<div style= "text-align:center;">''Message: Seepage and erosion along conduit must be taken seriously.''</div> ----</br> It is very common for dams to have poor compaction around the conduit. Water can flow along the conduit when fractures form in regions of poorly-compacted, low-density fill material. Fractures lead to internal erosion and the development of a void along the conduit. Content From Conduits through Embankment Dams (FEMA) <gallery mode="slideshow"> File...")
- 23:09, 21 June 2022 Camrenbt talk contribs uploaded File:SP2.jpg
- 23:09, 21 June 2022 Camrenbt talk contribs uploaded File:SP1.jpg
- 22:56, 21 June 2022 Camrenbt talk contribs created page Seepage and Piping (Created page with "Seepage near or around a conduit often indicates a problem is developing. Understanding the cause of the seepage is important to determining the path forward. ---- *Seepage and erosion around the conduit must be taken seriously *Seepage into pipe can go unnoticed for years until sinkhole develops *Deteriorated conduits with holes can cause seepage *Multiple Factors May Contribute to Internal Erosion Failures")
- 22:47, 21 June 2022 Camrenbt talk contribs created page File:LC1.jpg
- 22:47, 21 June 2022 Camrenbt talk contribs created page Longitudinal Cracking (Created page with "<div style= "text-align:center;">''Message: Longitudinal cracking in excess of 0.1 inch in width may indicate overloading or poor bedding.''</div> ----</br> Hairline longitudinal crack in the crown or invert indicate that the reinforcing steel has accepted part of the load. Cracks less than 0.01 inches in width are minor and only need to be noted. Cracks greater than hairline cracks, or those more than 0.01 inch in width but less than 0.1 inches (slightly more than the...")
- 22:47, 21 June 2022 Camrenbt talk contribs uploaded File:LC1.jpg
- 22:44, 21 June 2022 Camrenbt talk contribs created page File:Fixing Conduit.pdf
- 22:44, 21 June 2022 Camrenbt talk contribs uploaded File:Fixing Conduit.pdf
- 22:37, 21 June 2022 Camrenbt talk contribs created page File:Fix Leaky Conduit Document.pdf
- 22:37, 21 June 2022 Camrenbt talk contribs uploaded File:Fix Leaky Conduit Document.pdf
- 22:30, 21 June 2022 Camrenbt talk contribs created page File:Fix Leaky Conduit.pdf
- 22:30, 21 June 2022 Camrenbt talk contribs created page File:ES2.jpg
- 22:30, 21 June 2022 Camrenbt talk contribs created page File:ES1.jpg
- 22:30, 21 June 2022 Camrenbt talk contribs created page Exposed Steel (Created page with "<div style= "text-align:center;">''Message: Repair exposed steel as soon as possible.''</div> ----</br> Exposed steel due to spalling and cracking allows water to corrode the steel, which quickly weakens the pipe. If you have exposed steel, repair it quickly by cleaning and grouting the impacted location. <gallery mode="slideshow"> File:ES1.jpg|The Steel cylinder of this prestressed concrete cylinder conduit was visible in a recent inspection of this central montana da...")
- 22:30, 21 June 2022 Camrenbt talk contribs uploaded File:Fix Leaky Conduit.pdf
- 22:30, 21 June 2022 Camrenbt talk contribs uploaded File:ES2.jpg
- 22:30, 21 June 2022 Camrenbt talk contribs uploaded File:ES1.jpg
- 22:13, 21 June 2022 Camrenbt talk contribs created page File:Continuous flows pic.jpg
- 22:13, 21 June 2022 Camrenbt talk contribs created page Continuous Flows can Reduce Deterioration in Downstream Valves (Created page with "<div style= "text-align:center;">''Message: Deterioration of CMP does not occur at the same rate. Experience has shown us that the deterioration accelerates with time.''</div> ----</br> An inspection in 1999 showed this pipe to be in relatively good condition. 15 years later the pipe was completely corroded and failed. <gallery mode="slideshow"> File:Continuous flows pic.jpg| While the conduits may last a long time, holes can still develop in the pipe - as noted in thi...")
- 22:13, 21 June 2022 Camrenbt talk contribs uploaded File:Continuous flows pic.jpg
- 22:04, 21 June 2022 Camrenbt talk contribs created page File:SERVICE LIFE.jpg
- 22:04, 21 June 2022 Camrenbt talk contribs created page Service Life (Created page with "<div style= "text-align:center;">'' Message: Concrete conduits can last a very long time. A really old conduit may be in good condition and function properly.''</div> ----</br> <gallery mode="slideshow"> File:SERVICE LIFE.jpg|This Jefferson County, Montana dam is over 100 years old. The concrete conduit is still in good condition. </gallery> Category:Example Pages {{Revhistinf}}")
- 22:04, 21 June 2022 Camrenbt talk contribs uploaded File:SERVICE LIFE.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs created page File:JointD3.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs created page File:JointD2.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs created page File:JointD1.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs uploaded File:JointD3.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs uploaded File:JointD2.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs uploaded File:JointD1.jpg
- 21:54, 21 June 2022 Camrenbt talk contribs created page Joint Deterioration - Pay me now or pay me later (Created page with "<div style= "text-align:center;">''Message: Repair damaged concrete joints quickly.''</div> ----</br> Deterioration of concrete joints can repaired cost effectively – but it must be caught early. Once joint sealing compound is gone and gaskets start to appear, a major repair (sliplining or replacement) is on the horizon. <gallery mode="slideshow"> File:JD1.jpg|Joints were rapidly deteriorating in this eastern Montana dam File:JD2.jpg|Joint sealing compound was missin...")
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC4.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC3.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC2.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC1.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:Service Life.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs moved page Inspect Full Length Pipe to Inspect Full Length of Pipe
- 21:16, 21 June 2022 Camrenbt talk contribs created page Treatment Types (Created page with "<div style= "text-align:center;">''Message: Proper coatings significantly increase the performance of Corrugated Metal Pipe.''</div> ----</br> {{Picture |image= <!-- Add image file name (ex.image.jpg) --> Service Life.jpg |link= <!--Add link if applicable --> |caption= <!-- Add picture caption --> National Corrugated Steel Pipe Association 2008 }} '''Galvanized Steel Pipe''' Pre-galvanizing is the most widely used and most economical metallic coating for corrugated ste...")
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC4.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC3.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC2.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC1.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:Service Life.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page File:BC3.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page File:BC2.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page File:BC1.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page Bituminous Coating Impact on Design Life of Pipe (Created page with "<div style= "text-align:center;">''Message: Bituminous Coating significantly extends conduit design life.''</div> ----</br> This CMP conduit was recently removed from a Judith Basin County, MT dam. The pipe is still in acceptable structural condition, with no significant corrosion showing on the pipe interior. The bituminous coating was an integral component of the corrosion protection. <gallery mode="slideshow"> File:BC1.jpg|Recently removed bituminous coated CMP File...")