All public logs
Combined display of all available logs of ASDSO Dam Safety Toolbox. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
- 21:07, 21 June 2022 Camrenbt talk contribs uploaded File:BC3.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs uploaded File:BC2.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs uploaded File:BC1.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs created page File:CAR2.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs created page File:CAR1.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs created page Connection between Riser and Conduit often First to Fail (Created page with "<div style= "text-align:center;">''Message: Corrosion at the connection between a drop inlet and the conduit is the cause of many dam failures.''</div> ----</br> The connection between the drop pipe and the conduit can be difficult to evaluate. However, the condition of the connection is very important and corrosion can be a serious problem. Even if the rest of the pipe appears to be in good condition, the connection may not be. <gallery mode="slideshow"> File:CAR1.jpg...")
- 21:01, 21 June 2022 Camrenbt talk contribs uploaded File:CAR2.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs uploaded File:CAR1.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL6.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL5.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL4.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL3.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL2.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL1.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page Inspect Full Length Pipe (Created page with "<div style= "text-align:center;">''Message: Careful Inspection is required for CMP, even if the initial impression is good.''</div> ----</br> Upon initial inspection, a conduit may appear to be in decent condition with many years of service remaining. However, a simple observation at each end of a pipe will not provide enough information to determine the condition of a pipe. A camera inspection of the full length of a pipe will provide more detail and can often be done...")
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL6.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL5.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL4.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL3.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL2.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL1.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page File:COF3.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page File:COF2.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page File:COF1.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page Corrosion Occurs from Outside In (Created page with "<div style= "text-align:center;">''Message: Corrosion often begins outside and moves inside.''</div> ----</br> The soil surrounding a conduit can be more corrosive than the water inside the pipe. When this occurs, the pipe will corrode faster on the outside than the inside. By inspecting the inside of the pipe, it may appear to be in good condition, however, the pipe may be brittle due to corrosion on the outside. <gallery mode="slideshow"> File:COF1.jpg|This picture s...")
- 20:43, 21 June 2022 Camrenbt talk contribs uploaded File:COF3.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs uploaded File:COF2.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs uploaded File:COF1.jpg
- 15:44, 21 June 2022 Camrenbt talk contribs created page File:DaI3.jpg
- 15:44, 21 June 2022 Camrenbt talk contribs created page File:DaI2.png
- 15:44, 21 June 2022 Camrenbt talk contribs created page File:DaI1.png
- 15:44, 21 June 2022 Camrenbt talk contribs created page Deterioration at Invert is Hard to Detect (Created page with "<div style= "text-align:center;">''Message: The invert of a pipe is difficult to see and subject to increased corrosion.''</div> ----</br> This bituminous coated CMP showed only moderate deterioration in conduit. However, the connections between sections of the pipe and between the pipe and the tower were severely corroded. In addition, the coating at the invert of the pipe was gone and corrosion was beginning. Removal and replacement was needed. <gallery mode="slidesh...")
- 15:44, 21 June 2022 Camrenbt talk contribs uploaded File:DaI3.jpg
- 15:44, 21 June 2022 Camrenbt talk contribs uploaded File:DaI2.png
- 15:44, 21 June 2022 Camrenbt talk contribs uploaded File:DaI1.png
- 15:36, 21 June 2022 Camrenbt talk contribs created page File:USDA Decision Analysis Guide for Corrugated Metal Culvert Rehabilitation and Replacement Using Trenchless Technology.pdf
- 15:36, 21 June 2022 Camrenbt talk contribs uploaded File:USDA Decision Analysis Guide for Corrugated Metal Culvert Rehabilitation and Replacement Using Trenchless Technology.pdf
- 15:34, 21 June 2022 Camrenbt talk contribs created page File:EC4.jpg
- 15:34, 21 June 2022 Camrenbt talk contribs created page File:EC3.jpg
- 15:34, 21 June 2022 Camrenbt talk contribs created page File:EC2.jpg
- 15:34, 21 June 2022 Camrenbt talk contribs created page File:EC1.jpg
- 15:34, 21 June 2022 Camrenbt talk contribs created page Extent of Corrosion May Limit Repair Options (Created page with "<div style= "text-align:center;">''Message: The longer we wait, the fewer options we have. Understanding the severity of corrosion is important to recommend the appropriate rehab method.''</div> ----</br> Minor corrosion and abrasion can cause superficial rust and minor pitting and can be rehabilitated with a nonstructural method. Moderate corrosion leads to scattered heavy rusting and deep pitting and can be addressed with a semistructural rehabilitation method. Major...")
- 15:34, 21 June 2022 Camrenbt talk contribs uploaded File:EC4.jpg
- 15:34, 21 June 2022 Camrenbt talk contribs uploaded File:EC3.jpg
- 15:34, 21 June 2022 Camrenbt talk contribs uploaded File:EC2.jpg
- 15:34, 21 June 2022 Camrenbt talk contribs uploaded File:EC1.jpg
- 19:48, 20 June 2022 Camrenbt talk contribs created page Pipe Deterioration (Created page with "It is important to assess the condition of the conduit early in the process. Further actions all depend on this important factor. ---- ==CMP== Corrugated Metal Pipes (CMP) have been used for the outlet works in many small dams. Undetected corrosion or distress in the pipe is common, and may be an initiator of embankment piping. The deterioration of most old CMPs is an area of concern for dam owners, regulators, and engineers. Cases have been documented where CMP has det...")
- 19:40, 20 June 2022 Camrenbt talk contribs created page File:RD2.jpg
- 19:40, 20 June 2022 Camrenbt talk contribs created page File:RD1.png
- 19:40, 20 June 2022 Camrenbt talk contribs created page Example Pages (Created page with "{| class="wikitable sortable" style="width: 100%; background-color: #fff;" |- ! Topic !! Title |- | CMP Pipe Deterioration || Deterioration Accelerates with Time |}")