Siphons can pose Reservoir Level Control Challenges.: Difference between revisions
From ASDSO Dam Safety Toolbox
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
[[Category:Siphons]] | |||
---- | |||
''' ''Message: Considering a siphon as a [[replacement]] to a low level outlet? There may still be a need to passively control reservoir level.'' ''' | |||
''Message: Considering a siphon as a replacement to a low level outlet? There may still be a need to passively control reservoir level.'' | |||
<!-- Add body paragraphs here --> | <!-- Add body paragraphs here --> | ||
<gallery mode="slideshow" > | <gallery mode="slideshow" > | ||
<!-- Add image files here --> | <!-- Add image files here --> | ||
File:SR1.jpg|This small urban reservoir in Yellowstone County has a deteriorated outlet works. Used primarily for recreation and lawn irrigation, there is no need to make releases. | File:SR1.jpg|This small urban reservoir in Yellowstone County has a deteriorated outlet works. Used primarily for [[recreation]] and lawn [[irrigation]], there is no need to make releases. | ||
File:SR2.jpg|Abandonment of the outlet works and replacement with a siphon is a reasonable alternative to consider. However... | File:SR2.jpg|[[Abandonment]] of the outlet works and replacement with a siphon is a reasonable alternative to consider. However... | ||
File:SR3.jpg|The reservoir level is passively controlled with a drop inlet. Abandonment of the conduit also results in elimination of the drop inlet. Although offstream, the potential for over filling form the nearby canal remains. In addition to the installation of the siphon, other means must be considered to control the reservoir level. | File:SR3.jpg|The reservoir level is passively controlled with a drop inlet. Abandonment of the conduit also results in elimination of the drop inlet. Although offstream, the potential for over filling form the nearby canal remains. In addition to the installation of the siphon, other means must be considered to control the reservoir level. | ||
File:SR4.jpg|Lowering the auxiliary spillway is not practical. Other options must be considered which could include adding a high level overflow pipe for reservoir control. The siphon could then be available for emergency drawdown. | File:SR4.jpg|Lowering the auxiliary spillway is not practical. Other options must be considered which could include adding a high level overflow pipe for reservoir control. The siphon could then be available for emergency drawdown. |
Latest revision as of 03:19, 2 December 2022
Message: Considering a siphon as a replacement to a low level outlet? There may still be a need to passively control reservoir level.
Note: The content on this page was originally created as part of DamOutletWorks.org (DOWL, 2018). It has subsequently been updated and reformatted as part of the Dam Safety Toolbox.
Revision ID: 4747
Revision Date: 12/02/2022