ASDSO Dam Safety Toolbox

Siphons when regular releases aren't needed: Difference between revisions

From ASDSO Dam Safety Toolbox
Jump to: navigation, search
No edit summary
No edit summary
Line 1: Line 1:
<!--Example Page -->
[[Category:Outlet Configuration Outlet Works]]
<div style= "text-align:center;">
----
<!-- Add message here -->
''' ''Message: [[Siphon]] systems are an option for [[reservoirs]] that don’t make regular releases. Easy to construct and avoid the need for a penetration through the dam.'' '''
''Message: Siphon systems are an option for reservoirs that don’t make regular releases. Easy to construct and avoid the need for a penetration through the dam.''
 
</div>
----</br>
<!-- Add body paragraphs here -->
<!-- Add body paragraphs here -->
This central Montana reservoir use was changed from irrigation to recreation. As a result, there was no longer a need to make periodic releases. During rehabilitation, it was decided abandon the outlet and use a siphon. This eliminated the need to have a penetration through the dam and still provided emergency drawdown. Note that siphons have an operational limit depending on elevation and height of the dam.
This central [[Montana]] reservoir use was changed from [[irrigation]] to [[recreation]]. As a result, there was no longer a need to make periodic releases. During [[rehabilitation]], it was decided abandon the outlet and use a siphon. This eliminated the need to have a penetration through the dam and still provided emergency drawdown. Note that [[siphons]] have an operational limit depending on elevation and height of the dam.


[[File:Siphon1.jpg|center|700px]]
[[File:Siphon1.jpg|center|700px]]

Revision as of 02:57, 2 December 2022


Message: Siphon systems are an option for reservoirs that don’t make regular releases. Easy to construct and avoid the need for a penetration through the dam.

This central Montana reservoir use was changed from irrigation to recreation. As a result, there was no longer a need to make periodic releases. During rehabilitation, it was decided abandon the outlet and use a siphon. This eliminated the need to have a penetration through the dam and still provided emergency drawdown. Note that siphons have an operational limit depending on elevation and height of the dam.

This siphon was added after it was determined it was unnecessary to make periodic releases.


Note: The content on this page was originally created as part of DamOutletWorks.org (DOWL, 2018). It has subsequently been updated and reformatted as part of the Dam Safety Toolbox.
Revision ID: 4734
Revision Date: 12/02/2022