Many older dams were not constructed with a means of draining the reservoir. Lowering the reservoir may be needed for temporary [[construction]], for [[Emergency Response|emergency response]], or when regular releases aren't needed. Siphons can be a low-cost means of providing a reservoir outlet if one does not exist. The key operational parameters are: (1) the required hydraulic lift cannot exceed the effective local atmospheric pressure adjusted for vapor pressure and frictional losses; (2) the discharge point of the siphon must be lower in elevation than the body of water to be siphoned; and (3) the pipe or hose used for the siphon must be designed to operate at less than atmospheric pressures. Note that siphon outlets can be difficult to prime.
"Many older dams were not constructed with a means of draining the reservoir. Lowering the reservoir may be needed for temporary [[construction]], for [[Emergency Response|emergency response]], or when regular releases aren't needed. Siphons can be a low-cost means of providing a reservoir outlet if one does not exist. The key operational parameters are: (1) the required hydraulic lift cannot exceed the effective local atmospheric pressure adjusted for vapor pressure and frictional losses; (2) the discharge point of the siphon must be lower in elevation than the body of water to be siphoned; and (3) the pipe or hose used for the siphon must be designed to operate at less than atmospheric pressures. Note that siphon outlets can be difficult to prime."<ref name="DS-14">[[Design Standards No. 14: Appurtenant Structures for Dams (Ch. 4: General Outlet Works Design Considerations) | Design Standards No. 14: Appurtenant Structures for Dams (Ch. 4: General Outlet Works Design Considerations), Bureau of Reclamation, 2022]]</ref>


==Examples==
==Examples==
{{Website Icon}} [[Common Questions about Siphons|Get answers to some of the common questions about siphons]]
{{Website Icon}} [[Common Questions about Siphons | Get answers to some of the common questions about siphons]]


==Trainings==
==Trainings==

Latest revision as of 00:38, 14 December 2022


"Many older dams were not constructed with a means of draining the reservoir. Lowering the reservoir may be needed for temporary construction, for emergency response, or when regular releases aren't needed. Siphons can be a low-cost means of providing a reservoir outlet if one does not exist. The key operational parameters are: (1) the required hydraulic lift cannot exceed the effective local atmospheric pressure adjusted for vapor pressure and frictional losses; (2) the discharge point of the siphon must be lower in elevation than the body of water to be siphoned; and (3) the pipe or hose used for the siphon must be designed to operate at less than atmospheric pressures. Note that siphon outlets can be difficult to prime."[1]

Examples

Get answers to some of the common questions about siphons

Trainings

On-Demand Webinar: Design of Siphon Systems


Citations:


Revision ID: 5540