<!-- Introductory paragraph or topic page summary -->
<!-- Introductory paragraph or topic page summary -->
Many older dams were not constructed with a means of draining the reservoir. Lowering the reservoir may be needed for temporary [[construction]], for emergency response, or when regular releases aren't needed. Siphons can be a low-cost means of providing a reservoir outlet if one does not exist. The key operational parameters are: (1) the required hydraulic lift cannot exceed the effective local atmospheric pressure adjusted for vapor pressure and frictional losses; (2) the discharge point of the [[siphon]] must be lower in elevation than the body of water to be siphoned; (3) the pipe or hose used for the siphon must be designed to operate at less than atmospheric pressures; (4) siphon outlets should only be used when there are no other feasible options; and (5) siphon outlets are difficult to prime.
"Many older dams were not constructed with a means of draining the reservoir. Lowering the reservoir may be needed for temporary [[construction]], for [[Emergency Response|emergency response]], or when regular releases aren't needed. Siphons can be a low-cost means of providing a reservoir outlet if one does not exist. The key operational parameters are: (1) the required hydraulic lift cannot exceed the effective local atmospheric pressure adjusted for vapor pressure and frictional losses; (2) the discharge point of the siphon must be lower in elevation than the body of water to be siphoned; and (3) the pipe or hose used for the siphon must be designed to operate at less than atmospheric pressures. Note that siphon outlets can be difficult to prime."<ref name="DS-14">[[Design Standards No. 14: Appurtenant Structures for Dams (Ch. 4: General Outlet Works Design Considerations) | Design Standards No. 14: Appurtenant Structures for Dams (Ch. 4: General Outlet Works Design Considerations), Bureau of Reclamation, 2022]]</ref>


==Examples==
==Examples==
{{Website Icon}} [[Common Questions about Siphons|Get answers to some of the common questions about siphons]]
{{Website Icon}} [[Common Questions about Siphons | Get answers to some of the common questions about siphons]]


==Trainings==
==Trainings==

Latest revision as of 00:38, 14 December 2022


"Many older dams were not constructed with a means of draining the reservoir. Lowering the reservoir may be needed for temporary construction, for emergency response, or when regular releases aren't needed. Siphons can be a low-cost means of providing a reservoir outlet if one does not exist. The key operational parameters are: (1) the required hydraulic lift cannot exceed the effective local atmospheric pressure adjusted for vapor pressure and frictional losses; (2) the discharge point of the siphon must be lower in elevation than the body of water to be siphoned; and (3) the pipe or hose used for the siphon must be designed to operate at less than atmospheric pressures. Note that siphon outlets can be difficult to prime."[1]

Examples

Get answers to some of the common questions about siphons

Trainings

On-Demand Webinar: Design of Siphon Systems