ASDSO Dam Safety Toolbox

Importance of a Dry Trench During Construction with Concrete Cradle

From ASDSO Dam Safety Toolbox
Jump to: navigation, search

Message: Concrete pipe support blocks can settle in a wet trench, causing pipe to misalign.

This Dam was rehabilitated by replacing the last section of pipe with RCP. The pipe was set on support blocks and bedded with high-slump concrete. The trench was not dewatered adequately, causing the pipe support blocks to sink under the weight of the 48-inch concrete pipe. As the pipe settled, joints became misaligned.


Note: The content on this page was originally created as part of DamOutletWorks.org (DOWL, 2018). It has subsequently been updated and reformatted as part of the Dam Safety Toolbox.
Revision ID: 4766
Revision Date: 12/02/2022