ASDSO Dam Safety Toolbox

Design of Spillway Tainter Gates (EM 1110-2-2702)

From ASDSO Dam Safety Toolbox
Jump to: navigation, search

United State Army Corps of Engineers, 2000



This manual provides guidance for the design, fabrication, and inspection of spillway tainter gates, trunnion girder, and trunnion girder anchorage for navigation and flood control projects. Load and resistance factor design (LRFD) criteria are specified for design of steel components. Allowable stress design (ASD) criteria are provided in EM 1110-2-2105 and may be used only with prior approval of CECW-ET. Orthotropic shell, vertical framed, and stress skin-type tainter gates may be suitable in some locations but are not covered in this manual. Other types of control gates, including radial lock valves (reverse tainter valves) and sluice gates, may be referred to as tainter gates but also are not included in this manual.


Document Download:

2000 (current)


Errata/Special Notes:

None



Revision ID: 5906
Revision Date: 12/16/2022