Drain Sizing: Difference between revisions
No edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
[[Category:Seepage Analysis and Filter Design]] | [[Category:Seepage Analysis and Filter Design]] | ||
---- | ---- | ||
“The objective of [[Filters and Drains|filters and drains]] used as seepage control measures for embankments is to efficiently control the movement of water within and about the embankment. In order to meet this objective, filters and drains must, for the project life and with minimum maintenance, retain the protected materials, allow relatively free movement of water, and have sufficient discharge capacity. For design, these three necessities are termed piping or [[stability]] requirement, permeability requirement, and discharge capacity, respectively. The terms filters and drains are sometimes used interchangeably. Some definitions classify filters and drains by function. In this case, filters must retain the protected soil and have a permeability greater than the protected soil but do not need to have a particular flow or drainage capacity since flow will be perpendicular to the interface between the protected soil and filter. Drains, however, while meeting the requirements of filters, must have an adequate discharge capacity since drains collect seepage and conduct it to a discharge point or area. In practice, the critical element is not definition, but recognition, by the designer, when a drain must collect and conduct water. In this case the drain must be properly designed for the expected flows.”. <ref name="USACE">[[General Design and Construction Considerations for Earth and Rock-Fill Dams (EM 1110-2-2300) | EM 1110-2-2300 General Design and Construction Considerations for Earth and Rock-Fill Dams, USACE, 2004]]</ref> | “The objective of [[Filters and Drains|filters and drains]] used as seepage control measures for embankments is to efficiently control the movement of water within and about the embankment. In order to meet this objective, [[Filters and Drains|filters and drains]] must, for the project life and with minimum maintenance, retain the protected materials, allow relatively free movement of water, and have sufficient discharge capacity. For design, these three necessities are termed piping or [[stability]] requirement, permeability requirement, and discharge capacity, respectively. The terms filters and drains are sometimes used interchangeably. Some definitions classify filters and drains by function. In this case, filters must retain the protected soil and have a permeability greater than the protected soil but do not need to have a particular flow or drainage capacity since flow will be perpendicular to the interface between the protected soil and filter. Drains, however, while meeting the requirements of filters, must have an adequate discharge capacity since drains collect seepage and conduct it to a discharge point or area. In practice, the critical element is not definition, but recognition, by the designer, when a drain must collect and conduct water. In this case the drain must be properly designed for the expected flows.”. <ref name="USACE">[[General Design and Construction Considerations for Earth and Rock-Fill Dams (EM 1110-2-2300) | EM 1110-2-2300 General Design and Construction Considerations for Earth and Rock-Fill Dams, USACE, 2004]]</ref> | ||
==Examples== | ==Examples== | ||
Line 15: | Line 15: | ||
</br> | </br> | ||
{{ | {{Citations}} | ||
<!-- Revision history information --> | <!-- Revision history information --> | ||
{{revhistinf}} | {{revhistinf}} |
Revision as of 06:30, 14 December 2022
“The objective of filters and drains used as seepage control measures for embankments is to efficiently control the movement of water within and about the embankment. In order to meet this objective, filters and drains must, for the project life and with minimum maintenance, retain the protected materials, allow relatively free movement of water, and have sufficient discharge capacity. For design, these three necessities are termed piping or stability requirement, permeability requirement, and discharge capacity, respectively. The terms filters and drains are sometimes used interchangeably. Some definitions classify filters and drains by function. In this case, filters must retain the protected soil and have a permeability greater than the protected soil but do not need to have a particular flow or drainage capacity since flow will be perpendicular to the interface between the protected soil and filter. Drains, however, while meeting the requirements of filters, must have an adequate discharge capacity since drains collect seepage and conduct it to a discharge point or area. In practice, the critical element is not definition, but recognition, by the designer, when a drain must collect and conduct water. In this case the drain must be properly designed for the expected flows.”. [1]
Examples
Learn more about filters and drains for outlet works
Learn more good practices for pipe installation
Best Practices Resources
General Design and Construction Considerations for Earth and Rock-Fill Dams (EM 1110-2-2300)
Filters for Embankment Dams (FEMA)
Trainings
On-Demand Webinar: Filters and Drainage Systems for Embankment Dams
On-Demand Webinar: Internal Drainage Systems for Embankment Dams
Citations:
Revision ID: 5604
Revision Date: 12/14/2022