ASDSO Dam Safety Toolbox

Relief Wells: Difference between revisions

From ASDSO Dam Safety Toolbox
Jump to: navigation, search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 10: Line 10:
<!-- Add picture caption -->  
<!-- Add picture caption -->  
|caption= "Figure 7-9. Relief well seepage outflow. Although relief wells are not typically installed for the primary purpose of seepage water monitoring, their outflow can be collected, measured, and evaluated similar to open piezometers or observation wells."<ref name="FEMAP1032" />
|caption= "Figure 7-9. Relief well seepage outflow. Although relief wells are not typically installed for the primary purpose of seepage water monitoring, their outflow can be collected, measured, and evaluated similar to open piezometers or observation wells."<ref name="FEMAP1032" />
(Image Source: [https://commons.wikimedia.org/wiki/Category:Diamond_Valley_Lake#/media/File:DVL-Westdam.JPG FEMA])
}}  
}}  


Line 20: Line 21:


==Best Practices Resources==
==Best Practices Resources==
{{Document Icon}} [[Evaluation and Monitoring of Seepage and Internal Erosion (FEMA P-1032) | Evaluation and Monitoring of Seepage and Internal Erosion (FEMA P-1032), FEMA, 2015]]
{{Document Icon}} [[Evaluation and Monitoring of Seepage and Internal Erosion (FEMA P-1032) | Evaluation and Monitoring of Seepage and Internal Erosion (FEMA P-1032), FEMA]]
{{Document Icon}} [[Instrumentation of Embankment Dams and Levees (EM 1110-2-1908) | Instrumentation of Embankment Dams and Levees (EM 1110-2-1908), USACE, 2020]]
{{Document Icon}} [[Instrumentation of Embankment Dams and Levees (EM 1110-2-1908) | Instrumentation of Embankment Dams and Levees (EM 1110-2-1908), USACE]]


==Trainings==
==Trainings==

Latest revision as of 15:51, 18 July 2023


"Figure 7-9. Relief well seepage outflow. Although relief wells are not typically installed for the primary purpose of seepage water monitoring, their outflow can be collected, measured, and evaluated similar to open piezometers or observation wells."[1]

(Image Source: FEMA)

"All water retention structures are subject to seepage through their foundations and abutments. In many cases the seepage may result in excess hydrostatic pressures or uplift pressures beneath elements of the structure or landward strata. Relief wells are often installed to relieve these pressures which might otherwise endanger the safety of the structure. Relief wells, in essence, are nothing more than controlled artificial springs that reduce pressures to safe values and prevent the removal of soil via piping or internal erosion. The proper design, installation, and maintenance of relief wells are essential elements in assuring their effectiveness and the integrity of the protected structure."[2]

“Relief wells are typically vertical drains placed to relieve uplift pressure at the downstream toe of an embankment. Piezometers are typically located equidistant between two wells. Under maximum hydraulic load, the piezometric level at the downstream toe of an embankment should be lower than the ground surface”.[3]

"Relief wells also function as observation wells, but their primary purpose is to reduce the hydraulic head at selected locations along the seepage flow path... Relief wells for dams have specific problems associated with the plugging of the filter packs or the accumulation of bacteria or carbonates (USACE, 1995). It is often necessary to install piezometers adjacent to relief wells to measure and monitor the pressure increases associated with clogged wells. Relief wells typically require regular maintenance for long-term proper functioning, including re-development, chemical treatments, and disinfection."[1]

Best Practices Resources

Evaluation and Monitoring of Seepage and Internal Erosion (FEMA P-1032), FEMA

Instrumentation of Embankment Dams and Levees (EM 1110-2-1908), USACE

Trainings

On-Demand Webinar: Evaluation and Maintenance of Piezometers, Relief Wells, and Drains in Dams and Levees