(Created page with "__NOTOC__ Category:Energy Dissipation ---- Type II and Type III stilling basins reduce the energy of the flow discharging from a spillway and allow the water to enter the outlet channel at a reduced velocity. Type II basins contain chute blocks at the upstream end and a dentated (tooth-like) endsill. Baffle piers are not used in a Type II basin because of the high velocity water entering the basin. Type III energy dissipators can be used if the entering flow velocit...")
 
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 3: Line 3:
----
----


Type II and Type III stilling basins reduce the energy of the flow discharging from a spillway and allow the water to enter the outlet channel at a reduced velocity. Type II basins contain chute blocks at the upstream end and a dentated (tooth-like) endsill. Baffle piers are not used in a Type II basin because of the high velocity water entering the basin. Type III energy dissipators can be used if the entering flow velocity is not high (less than 50 feet per second ([[Hydraulic Design of Stilling Basins and Energy Dissipators]], USBR, 1984)). Type III basins contain baffle piers which are located on the stilling basin apron downstream of the chute blocks. Located at the end of both types of USBR stilling basins is an endsill, which may be leveled or sloped, that creates a tailwater to reduce the velocity of the flow leaving the basin. <ref name="ASDSO">[https://damsafety.org/dam-owners/outlet-erosion-control-structures ASDSO, 2022]</ref>
Type II and Type III stilling basins reduce the energy of the flow discharging from a spillway and allow the water to enter the outlet channel at a reduced velocity. Type II basins contain chute blocks at the upstream end and a dentated (tooth-like) endsill. Baffle piers are not used in a Type II basin because of the high velocity water entering the basin. Type III energy dissipators can be used if the entering flow velocity is not high (less than 50 feet per second ([[Hydraulic Design of Stilling Basins and Energy Dissipators]], USBR, 1984). Type III basins contain baffle piers which are located on the stilling basin apron downstream of the chute blocks. Located at the end of both types of USBR stilling basins is an endsill, which may be leveled or sloped, that creates a tailwater to reduce the velocity of the flow leaving the basin. <ref name="ASDSO">[https://damsafety.org/dam-owners/outlet-erosion-control-structures ASDSO, 2022]</ref>
==Examples==
{{Website Icon}} [[Hydraulic Jump Stilling Basin Examples | See examples of energy dissipation using stilling basins]]


<!-- For information on notation for in text citations visit https://www.mediawiki.org/wiki/Help:Cite  Or simply enclose the citation as shown <ref> citation </ref> in the location of the in text mention. Citations will automatically populate below-->
<!-- For information on notation for in text citations visit https://www.mediawiki.org/wiki/Help:Cite  Or simply enclose the citation as shown <ref> citation </ref> in the location of the in text mention. Citations will automatically populate below-->

Latest revision as of 23:32, 13 December 2022


Type II and Type III stilling basins reduce the energy of the flow discharging from a spillway and allow the water to enter the outlet channel at a reduced velocity. Type II basins contain chute blocks at the upstream end and a dentated (tooth-like) endsill. Baffle piers are not used in a Type II basin because of the high velocity water entering the basin. Type III energy dissipators can be used if the entering flow velocity is not high (less than 50 feet per second (Hydraulic Design of Stilling Basins and Energy Dissipators, USBR, 1984). Type III basins contain baffle piers which are located on the stilling basin apron downstream of the chute blocks. Located at the end of both types of USBR stilling basins is an endsill, which may be leveled or sloped, that creates a tailwater to reduce the velocity of the flow leaving the basin. [1]

Examples

See examples of energy dissipation using stilling basins