Gate Performance: Difference between revisions
No edit summary |
No edit summary |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
[[Category:Structural Surveillance and Monitoring]] | |||
---- | ---- | ||
<!-- Delete any sections that are not necessary to your topic. Add pictures/sections as needed --> | <!-- Delete any sections that are not necessary to your topic. Add pictures/sections as needed --> | ||
[ | Radial gates and other types of gate systems can be subjected to a range of loading conditions and can experience corrosion or other weakening over time. Strain gages are commonly used to monitor gate performance. “Two types of gages are generally used for measuring strains: surface gages and internal or embedded gages. These types can be further divided into short- and long-term gages, depending on the duration of measurements. Usually, short-term strains are best measured by electrical type gages, while some long-term strains (e.g., creep and shrinkage) can be conveniently measured using detachable mechanical gages”.<ref name="EM 1110-2-4300">[[Instrumentation for Concrete Structures (EM 1110-2-4300) | EM 1110-2-4300 Instrumentation for Concrete Structures, USACE, 1987]]</ref> | ||
Electrical hoist current draw is another means of monitoring gate performance. | |||
==Examples== | ==Examples== | ||
{{Website Icon}} | {{Website Icon}} [https://damfailures.org/case-study/folsom-dam-california-1995/ Learn more about the importance of monitoring and inspecting gates from the gate failure at Folsom Dam (DamFailures.org)] | ||
==Best Practices Resources== | ==Best Practices Resources== | ||
{{Document Icon}} [[Instrumentation for Concrete Structures (EM 1110-2-4300)|Instrumentation for Concrete Structures (EM 1110-2-4300) (U.S. Army Corps of Engineers)]] | {{Document Icon}} [[Instrumentation for Concrete Structures (EM 1110-2-4300)|Instrumentation for Concrete Structures (EM 1110-2-4300) (U.S. Army Corps of Engineers)]] |
Latest revision as of 20:50, 6 December 2022
Radial gates and other types of gate systems can be subjected to a range of loading conditions and can experience corrosion or other weakening over time. Strain gages are commonly used to monitor gate performance. “Two types of gages are generally used for measuring strains: surface gages and internal or embedded gages. These types can be further divided into short- and long-term gages, depending on the duration of measurements. Usually, short-term strains are best measured by electrical type gages, while some long-term strains (e.g., creep and shrinkage) can be conveniently measured using detachable mechanical gages”.[1]
Electrical hoist current draw is another means of monitoring gate performance.
Examples
Best Practices Resources
Instrumentation for Concrete Structures (EM 1110-2-4300) (U.S. Army Corps of Engineers)
Citations:
Revision ID: 5005
Revision Date: 12/06/2022