ASDSO Dam Safety Toolbox

Uncontrolled Spillways: Difference between revisions

From ASDSO Dam Safety Toolbox
Jump to: navigation, search
No edit summary
 
(One intermediate revision by one other user not shown)
Line 17: Line 17:
“A controlled crest is one that includes gates which are used to control the flow; the uncontrolled crest is one unencumbered by gates”.<ref name="EM 1110-2-1603">[[Hydraulic Design of Spillways (EM 1110-2-1603) | EM 1110-2-1603 Hydraulic Design of Spillways, USACE, 1992]]</ref>
“A controlled crest is one that includes gates which are used to control the flow; the uncontrolled crest is one unencumbered by gates”.<ref name="EM 1110-2-1603">[[Hydraulic Design of Spillways (EM 1110-2-1603) | EM 1110-2-1603 Hydraulic Design of Spillways, USACE, 1992]]</ref>


“Common to all uncontrolled [[spillways]] that are not integral with a concrete dam (i.e., located away from the dam on or through abutments, or on or through reservoir rim) is that existing topography must provide adequate space without excessive excavation. Also, the existing topography must allow appropriate orientation (alignment of the spillway between the reservoir and downstream river or stream) of the conveyance feature and terminal structure. Additionally, economics will come into play for all uncontrolled spillways”.<ref name="DS14">[[Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations) | Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations), USBR, 2014]]</ref>
“Common to all uncontrolled [[spillways]] that are not integral with a concrete dam (i.e., located away from the dam on or through abutments, or on or through reservoir rim) is that existing topography must provide adequate space without excessive excavation. Also, the existing topography must allow appropriate orientation (alignment of the spillway between the reservoir and downstream river or stream) of the conveyance feature and terminal structure. Additionally, economics will come into play for all uncontrolled spillways”.<ref name="DS14">[[Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations) | Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations), USBR, 2022]]</ref>


==Types of Uncontrolled Spillways==
==Types of Uncontrolled Spillways==
Line 26: Line 26:


<noautolinks>==Best Practices Resources==</noautolinks>
<noautolinks>==Best Practices Resources==</noautolinks>
{{Document Icon}} [[Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations) | Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations), USBR, 2022]]
{{Document Icon}} [[Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations) | Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations), USBR]]
{{Document Icon}} [[National Engineering Handbook: Chapter 50 - Earth Spillway Design | National Engineering Handbook: Chapter 50 - Earth Spillway Design, NRCS, 2014]]
{{Document Icon}} [[National Engineering Handbook: Chapter 50 - Earth Spillway Design | National Engineering Handbook: Chapter 50 - Earth Spillway Design, NRCS]]
{{Document Icon}} [[Hydraulic Design of Spillways (EM 1110-2-1603) | Hydraulic Design of Spillways (EM 1110-2-1603), USACE, 1992]]
{{Document Icon}} [[Hydraulic Design of Spillways (EM 1110-2-1603) | Hydraulic Design of Spillways (EM 1110-2-1603), USACE]]


==Trainings==
==Trainings==

Latest revision as of 19:20, 11 July 2023


A stepped chute spillway in England. (Wikipedia)

“A controlled crest is one that includes gates which are used to control the flow; the uncontrolled crest is one unencumbered by gates”.[1]

“Common to all uncontrolled spillways that are not integral with a concrete dam (i.e., located away from the dam on or through abutments, or on or through reservoir rim) is that existing topography must provide adequate space without excessive excavation. Also, the existing topography must allow appropriate orientation (alignment of the spillway between the reservoir and downstream river or stream) of the conveyance feature and terminal structure. Additionally, economics will come into play for all uncontrolled spillways”.[2]

Types of Uncontrolled Spillways

Best Practices Resources

Design Standards No. 14: Appurtenant Structures for Dams (Ch. 3: General Spillway Design Considerations), USBR

National Engineering Handbook: Chapter 50 - Earth Spillway Design, NRCS

Hydraulic Design of Spillways (EM 1110-2-1603), USACE

Trainings

On-Demand Webinar: Introduction to Earth Spillway Design and Evaluation

On-Demand Webinar: Dam Safety with 3D Weirs

On-Demand Webinar: Hydraulic Design of Labyrinth Weirs



Citations:


Revision ID: 7133
Revision Date: 07/11/2023